Toxic Combustion Gas LCD CO Analyzer Portable Single Gas Detector Zetron MS600

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | Portable CO Gas Detector | Alarm Mode | Vibration, Visual, Audible |
---|---|---|---|
Explosion-proof Mark | Exia II CT6 | Display Mode | 2.5-inch High-definition Color Screen |
Display | LCD | Data Transfer | USB |
Warranty | 1 Year | Size | 180×78×33mm (L×W×H) |
Highlight | LCD Co Analyzer,Zetron Co Analyzer,LCD Combustion Gas Analyzer |
Graphical display, and use the form of the curve to reflect the trend of gas concentration changes in a certain period of time. Data recovery function; in case of misoperation, it is possible to select partial or full recovery. It is possible to set whether to display the maximum value, minimum value, average value, or not. Standard USB charging port, with charging protection function, USB hot plug supported, and the charging status instrument can work properly. 4600mA high-capacity rechargeable polymer battery is adopted, so it is possible to work for a long period of time. High-precision temperature and humidity measurements (optional configuration).
Gases to be detected
|
Range
|
Accurancy
|
Resolution
|
Response time T90
|
Carbon monoxide ( CO )
|
0-500ppm
|
<±2%(F.S)
|
0.01ppm
|
≤30 seconds
|
Sulfur dioxide ( SO2 )
|
0-100ppm
|
<±2%(F.S)
|
0.01ppm
|
≤30 seconds
|
Nitric oxide ( NO )
|
0-100ppm
|
<±2%(F.S)
|
0.01ppm
|
≤30 seconds
|
Nitrogen dioxide ( NO2 )
|
0-100ppm
|
<±2%(F.S)
|
0.01ppm
|
≤25 seconds
|
Nitrogen oxide ( NOX )
|
0-100ppm
|
<±2%(F.S)
|
0.01ppm
|
≤30 seconds
|
Carbon disulfide ( CS2 )
|
0-50ppm
|
<±2%(F.S)
|
0.01ppm
|
≤30 seconds
|
Acrylonitrile ( C3H3N )
|
0-50ppm
|
<±2%(F.S)
|
0.01ppm
|
≤30 seconds
|
Iodine gas ( I2 )
|
0-50ppm
|
<±2%(F.S)
|
0.01ppm
|
≤30 seconds
|