loading

Zetron Technology - Environmental Monitoring Instruments & Gas Detection Solutions.


TA-201E Total Organic Carbon Analyzer for Pharmaceutical Water Testing 1
TA-201E Total Organic Carbon Analyzer for Pharmaceutical Water Testing 1

TA-201E Total Organic Carbon Analyzer for Pharmaceutical Water Testing

The TA-201E Total Organic Carbon Analyzer provides precise measurement of organic carbon levels, ensuring compliance with regulatory standards in various industries. With its user-friendly interface and efficient analysis capabilities, it streamlines the process of water quality testing for environmental monitoring and industrial applications.

5.0
design customization

    oops...!

    no product data.

    Go to homepage
    1 (41)

    Overview

    TA-201E adopts the high-temperature catalytic combustion oxidation method, the specimen together with the purification gas (high purity oxygen) are introduced into the high-temperature combustion tube and the low-temperature reaction tube respectively, the specimen through the high-temperature combustion tube is catalytically oxidised by the high temperature, and the organic carbon and inorganic carbon therein are converted into carbon dioxide, and the inorganic carbon therein is decomposed into carbon dioxide after the acidification of the specimen through the low-temperature reaction tube; 


    The carbon dioxide produced by both reaction tubes is introduced into the non-dispersive infrared gas detector NDIR in turn through carriTer gas transport, and COThe carbon dioxide produced in the two reaction tubes is sequentially introduced into the non-dispersive infrared gas detector (NDIR) through gas transport, and CO₂ is detected. Thus, the total carbon (TC) and inorganic carbon (IC) in the water are measured separately.The difference between TC and IC is the total organic carbon (TOC).That is: TOC = TC - IC

    Features

    ▪ High-temperature catalytic oxidation can efficiently oxidize difficult-to-digest organic carbon, making the product easy to analyze high-concentration TOC samples;

    ▪ Rapid analysis (1-4 minutes);

    ▪ Higher safety, the combustion furnace heating adopts multiple protections, and the overheating protection circuit is independent of the temperature control system. Overheating can automatically cut off the heating to ensure product safety;

    ▪ Real-time flow monitoring to maintain flow stability and ensure data reliability;

    ▪ The pipeline can be cleaned and purged in all directions. The internal circuit can be cleaned according to the needs and operating requirements, which greatly reduces the failure rate and instrument maintenance time;

    undefined

    ▪ The instrument automatically discharges waste, automatically discharges and feeds acid, and the acid inlet amount is controlled stably;

    ▪ Less sample and reagent consumption, each measurement requires 0.5μL of high-purity water, 2ml of acid reagent (for IC testing), and about 2000ml of high-purity oxygen (under standard conditions, flow rate 100ml/min, ventilation time 20min.);

    ▪ The CO₂ detection of the NDIR detector has good linearity and high accuracy. The CO₂ signal is converted into a peak curve, and then the built-in data processor calculates the TOC value (the difference between TC and IC);

    ▪ The catalytic combustion oxidation method has strong oxidation ability and can oxidize almost all organic matter with stable performance. The 680℃ combustion method is almost below the melting point of all salts, which can extend the life of the catalyst and combustion tube, which is especially important when the measurement object is a water sample containing salt;

    ▪ The instrument uses a high-resolution 7-inch touch wide screen and adopts an intelligent system for easy operation.

    undefined

    Parameters

    ModelTA-201E
    Measurement range0~1000mg/L (non-dilution state), dilution state can reach 0~30000mg/L
    Repeatability≤ 3%
    Indication errorTC; ±0.1%F.S or ±5% (the larger one) IC; ±0.1%F.S or ±4% (the larger one)
    LinearityR2≥99.9%
    Lower detection limit0.5mg/L
    Analysis time2~4min
    Injection volume10μL~500μL
    External storageU disk
    Power supplyAC 220V±10% 50/60Hz (reliable grounding required)
    Power1000W when the electric furnace is heated
    Ambient temperature0~40℃
    Relative humidity10~85%
    Setting locationIndoor
    Gas sourcehigh-purity oxygen (≥99.999%)
    High purity WaterCarbon dioxide-free water (TOC≤0.5mg/L)
    Acid reagent10% phosphoric acid
    Instrument placementThere must be 20cm of space around for heat dissipation, and no items can be stacked on top
    Combustion temperature680℃~1200℃

    Application Scenes

    Determination of total organic carbon (TOC) in surface water, groundwater, domestic sewage, industrial wastewater, applied to environmental monitoring, urban water supply and drainage, disease control, chemical power and other industries.

    undefined
    Related Products
    TA-3.5 Online TOC Analyzer for Continuous Water Monitoring
    The TA-3.5 Online TOC Analyzer is an advanced tool designed for real-time measurement of total organic carbon (TOC) levels in various water samples. With its user-friendly interface and precise analytical capabilities, it enables efficient monitoring and assessment of water quality, making it an essential resource for environmental research and industrial applications.
    MS600-FG2 Portable Flue Gas Analyzer for Combustion and Emission Testing
    The MS600-FG2 Portable Flue Gas Analyzer is a compact and efficient instrument designed for real-time measurement of flue gas emissions, ensuring compliance with environmental regulations. With its user-friendly interface and advanced sensor technology, it provides accurate readings for various gases, making it an essential tool for technicians in the heating and HVAC industries.
    ZAWA5636-4 Class 2 Sound Level Meter
    A compact sound level meter with noise exposure functions for workplace and environmental measurements.
    ZAWA5688 Class 2 Sound Level Meter
    A modular handheld instrument for environmental and industrial noise surveys, workplace noise assessments, boundary measurements and impulse or peak noise testing.
    ZAWA5636-4 Class 2 Sound Level Meter
    A compact sound level meter with noise exposure functions for workplace and environmental measurements.
    ZAWA5688 Class 2 Sound Level Meter
    A modular handheld instrument for environmental and industrial noise surveys, workplace noise assessments, boundary measurements and impulse or peak noise testing.
    PTM300-DUAL Dual-Channel Portable GC
    Two independent precision chromatographic channels support rapid on-site analysis of complex VOC mixtures.
    PTM300 Portable Gas Chromatograph
    A portable GC with a sensitive PID and controlled column temperature for ppb-level detection without sample preconcentration.
    Now let's talk about the product you want.
    O3@bjzetron.com
    +86-15699785629
    We aim to be a trusted long-term partner for organizations that need dependable gas detection, air-quality monitoring, VOC monitoring, and emissions-monitoring solutions.
    Contact Us
    Contact Person: Lisa Niu
    Phone Number: +86-15699785629
    WhatsApp: +86-15699785629
    Company Address: Room 19B, 17th Floor, Building 1, No. 48 Dongzhimenwai Avenue, Dongcheng District, Beijing
    Copyright © 2026 Zetron Technology - www.multigas-detector.com | Sitemap | Privacy Policy
    Product Lives
    Customer service