TA-201E Total Organic Carbon Analyzer for Pharmaceutical Water Testing 1
TA-201E Total Organic Carbon Analyzer for Pharmaceutical Water Testing 1

TA-201E Total Organic Carbon Analyzer for Pharmaceutical Water Testing

The TA-201E Total Organic Carbon Analyzer provides precise measurement of organic carbon levels, ensuring compliance with regulatory standards in various industries. With its user-friendly interface and efficient analysis capabilities, it streamlines the process of water quality testing for environmental monitoring and industrial applications.

5.0
design customization

    oops...!

    no product data.

    Go to homepage
    1 (41)

    Overview

    TA-201E adopts the high-temperature catalytic combustion oxidation method, the specimen together with the purification gas (high purity oxygen) are introduced into the high-temperature combustion tube and the low-temperature reaction tube respectively, the specimen through the high-temperature combustion tube is catalytically oxidised by the high temperature, and the organic carbon and inorganic carbon therein are converted into carbon dioxide, and the inorganic carbon therein is decomposed into carbon dioxide after the acidification of the specimen through the low-temperature reaction tube; 


    The carbon dioxide produced by both reaction tubes is introduced into the non-dispersive infrared gas detector NDIR in turn through carriTer gas transport, and COThe carbon dioxide produced in the two reaction tubes is sequentially introduced into the non-dispersive infrared gas detector (NDIR) through gas transport, and CO₂ is detected. Thus, the total carbon (TC) and inorganic carbon (IC) in the water are measured separately.The difference between TC and IC is the total organic carbon (TOC).That is: TOC = TC - IC

    Features

    ▪ High-temperature catalytic oxidation can efficiently oxidize difficult-to-digest organic carbon, making the product easy to analyze high-concentration TOC samples;

    ▪ Rapid analysis (1-4 minutes);

    ▪ Higher safety, the combustion furnace heating adopts multiple protections, and the overheating protection circuit is independent of the temperature control system. Overheating can automatically cut off the heating to ensure product safety;

    ▪ Real-time flow monitoring to maintain flow stability and ensure data reliability;

    ▪ The pipeline can be cleaned and purged in all directions. The internal circuit can be cleaned according to the needs and operating requirements, which greatly reduces the failure rate and instrument maintenance time;

    undefined

    ▪ The instrument automatically discharges waste, automatically discharges and feeds acid, and the acid inlet amount is controlled stably;

    ▪ Less sample and reagent consumption, each measurement requires 0.5μL of high-purity water, 2ml of acid reagent (for IC testing), and about 2000ml of high-purity oxygen (under standard conditions, flow rate 100ml/min, ventilation time 20min.);

    ▪ The CO₂ detection of the NDIR detector has good linearity and high accuracy. The CO₂ signal is converted into a peak curve, and then the built-in data processor calculates the TOC value (the difference between TC and IC);

    ▪ The catalytic combustion oxidation method has strong oxidation ability and can oxidize almost all organic matter with stable performance. The 680℃ combustion method is almost below the melting point of all salts, which can extend the life of the catalyst and combustion tube, which is especially important when the measurement object is a water sample containing salt;

    ▪ The instrument uses a high-resolution 7-inch touch wide screen and adopts an intelligent system for easy operation.

    undefined

    Parameters

    Model TA-201E
    Measurement range 0~1000mg/L (non-dilution state), dilution state can reach 0~30000mg/L
    Repeatability ≤ 3%
    Indication error TC; ±0.1%F.S or ±5% (the larger one) IC; ±0.1%F.S or ±4% (the larger one)
    Linearity R2≥99.9%
    Lower detection limit 0.5mg/L
    Analysis time 2~4min
    Injection volume 10μL~500μL
    External storage U disk
    Power supply AC 220V±10% 50/60Hz (reliable grounding required)
    Power 1000W when the electric furnace is heated
    Ambient temperature 0~40℃
    Relative humidity 10~85%
    Setting location Indoor
    Gas source high-purity oxygen (≥99.999%)
    High purity Water Carbon dioxide-free water (TOC≤0.5mg/L)
    Acid reagent 10% phosphoric acid
    Instrument placement There must be 20cm of space around for heat dissipation, and no items can be stacked on top
    Combustion temperature 680℃~1200℃

    Application Scenes

    Determination of total organic carbon (TOC) in surface water, groundwater, domestic sewage, industrial wastewater, applied to environmental monitoring, urban water supply and drainage, disease control, chemical power and other industries.

    undefined
    Related Products
    TA-3.5 Online TOC Analyzer for Continuous Water Monitoring
    The TA-3.5 Online TOC Analyzer is an advanced tool designed for real-time measurement of total organic carbon (TOC) levels in various water samples. With its user-friendly interface and precise analytical capabilities, it enables efficient monitoring and assessment of water quality, making it an essential resource for environmental research and industrial applications.
    AD310-STS Gas Dilution and Humidity System
    An integrated industrial calibration platform combining thermal mass-flow control, multistage dilution and a two-stage split-flow humidity generator.
    AD310L Standard Gas Generator
    A stationary laboratory system for precise dynamic generation of standard gases.
    AD310MMulti-Channel Gas Dilution Calibrator
    An industrial gas-mixing and dilution platform combining an embedded industrial computer with precision mass-flow controllers.
    AD310L Standard Gas Generator
    A stationary laboratory system for precise dynamic generation of standard gases.
    AD310MMulti-Channel Gas Dilution Calibrator
    An industrial gas-mixing and dilution platform combining an embedded industrial computer with precision mass-flow controllers.
    AD310C Sonic-Nozzle Gas Dilution Calibrator
    A trace-organic-gas dilution platform based on sonic-nozzle flow control, temperature stabilization and inert flow paths.
    PTM300S Portable GC-FID Analyzer
    A portable GC-FID analyzer for field measurement of total hydrocarbons, methane and NMHC in ambient air and exhaust gas.
    Now let's talk about the product you want.
    rainy@hiyipro.com
    +86-15699785629
    Lisa Niu
    We aim to be a trusted long-term partner for organizations that need dependable gas detection, air-quality monitoring, VOC monitoring, and emissions-monitoring solutions.
    Contact Us
    Contact Person: Lisa Niu
    Phone Number: +86-15699785629
    WhatsApp: +86-15699785629
    Company Address: Room 19B, 17th Floor, Building 1, No. 48 Dongzhimenwai Avenue, Dongcheng District, Beijing
    Copyright © 2026 Zetron Technology - www.multigas-detector.com | Sitemap | Privacy Policy
    Customer service
    detect