    Class 1 Sound Level Meter

    A handheld acoustic measurement platform for environmental noise, industrial noise profiling, workplace assessment, impulse noise and C-weighted peak measurements.

    Key Features

    • 20 to 142 dB measurement range, with peak measurement up to 145 dB.
    • Class 1 sound level and octave-band analysis; 24-bit conversion at 48 kHz.
    • Simultaneous integration, statistics, octave analysis and noise dose measurement with enabled modules.
    • Color display, PC connectivity and configurable audio recording.
    • Optional GPS and reverberation-time analysis support more detailed investigations.

    Acoustic Performance

    Parameter Specification
    Standards IEC 61672 Class 1; IEC 61260 Class 1; IEC 61252:2002
    Additional listed standards IEC 60651:2001 Type 1; IEC 60804:2000 Type 1; ANSI S1.4:1983 Type 1; ANSI S1.4A:1985 Type 1; ANSI S1.43:1997 Type 1; ANSI S1.25:1991
    Marking CE marking listed in the supplied instrument specification
    Microphone 1/2-inch prepolarized condenser microphone; sensitivity level -28 dB
    Preamplifier Removable ZAWA14601
    Frequency range 10 Hz to 20 kHz, ±1 dB, excluding microphone
    Measurement range 20 to 142 dB; 145 dB peak
    Self-generated noise <12 dB(A), <17 dB(C), <22 dB(Z)
    Frequency weightings Simultaneous A, C, Z, B, D and two user-defined weightings
    Time weightings Simultaneous F, S, I and Peak
    A/D conversion 24 bits
    Sampling frequency 48 kHz
    Calibration Class 1 acoustic calibrator; verify compatible model before ordering
    Internal memory 32 Mb flash memory
    Integration result storage 3,328 groups
    Statistical result storage 3,328 groups with the same indices in both analyzers; 2,663 groups with different indices
    SD card Optional 32 GB SD card; requires the appropriate program
    Display 240 × 320 color display; adjustable brightness; backlight can be switched off
    Display resolution 0.1 dB
    Low battery indication On-screen symbol
    Start delay 0 to 99 s
    Back erase Excludes undesired noise events from the measurement

    Acoustic Performance

    Parameter Specification
    Standards IEC 61672 Class 1; IEC 61260 Class 1; IEC 61252:2002
    Additional listed standards IEC 60651:2001 Type 1; IEC 60804:2000 Type 1; ANSI S1.4:1983 Type 1; ANSI S1.4A:1985 Type 1; ANSI S1.43:1997 Type 1; ANSI S1.25:1991
    Marking CE marking listed in the supplied instrument specification
    Microphone 1/2-inch prepolarized condenser microphone; sensitivity level -28 dB
    Preamplifier Removable ZAWA14601
    Frequency range 10 Hz to 20 kHz, ±1 dB, excluding microphone
    Measurement range 20 to 142 dB; 145 dB peak
    Self-generated noise <12 dB(A), <17 dB(C), <22 dB(Z)
    Frequency weightings Simultaneous A, C, Z, B, D and two user-defined weightings
    Time weightings Simultaneous F, S, I and Peak
    A/D conversion 24 bits
    Sampling frequency 48 kHz
    Calibration Class 1 acoustic calibrator; verify compatible model before ordering
    Internal memory 32 Mb flash memory
    Integration result storage 3,328 groups
    Statistical result storage 3,328 groups with the same indices in both analyzers; 2,663 groups with different indices
    SD card Optional 32 GB SD card; requires the appropriate program
    Display 240 × 320 color display; adjustable brightness; backlight can be switched off
    Display resolution 0.1 dB
    Low battery indication On-screen symbol
    Start delay 0 to 99 s
    Back erase Excludes undesired noise events from the measurement

    Acoustic Performance Continued

    Parameter Specification
    Parameter Diffuse-field correction for ANSI S1.4

    Calibration note: the technical table lists ZAWA6021A while the accessories list names ZAWA6221A. Compatibility must be confirmed.

    Measurement and Spectral Analysis

    Parameter Specification
    Integration parameters LXYi, LXYp, LXeq,t, LXeq,T, LXmax, LXmin, LXpeak, LAE, LC-A and SEL
    Integration time 1 s to 99 h 59 min 59 s
    Display modes Simple, List, Huge and Big
    Statistical parameters LXYp, LXeq,0.5s, LXeq,T, LXYmax, LXYmin, LXYeqT, SEL, LN and SD
    24-hour monitoring Automatic measurements of Ld, Ln and Ldn
    Statistical analyzers Two independently weighted analyzers; each provides seven preset and seven user-defined percentiles, up to 28 LN values in total
    Preset percentiles L1, L5, L10, L50, L90, L95 and L99; 0.1 dB resolution
    Octave filters Parallel 1/1-octave filters; IEC 61260:1995 Class 1; base G10 = 10^(3/10)
    Octave bands 11 bands from 16 Hz to 16 kHz: 16, 31.5, 63, 125, 250, 500, 1,000, 2,000, 4,000, 8,000 and 16,000 Hz
    Third-octave filters Parallel 1/3-octave filters; IEC 61260:1995 Class 1
    Third-octave bands 33 bands from 12.5 Hz to 20 kHz
    Spectral analysis rate 50 analyses/s; level linear range >110 dB
    Spectral parameters LXYp, LXeq,0.5s, LXeq,T, LXYmax, LXYmin and Tm; list and graph displays
    Spectral weighting Selectable A, C and Z; band-center results also available
    Noise rating Real-time NR and NC values and curves; NR reference ISO 1996:1971; NC reference ANSI S2.12-2008
    FFT analysis 2,048 lines; sampling frequencies 48, 24, 12, 6 and 3 kHz
    FFT results MAX, MIN and LeqT
    FFT windows Hanning, flat-top and rectangular; an additional window designation requires confirmation

    Notation: X denotes A, C or Z frequency weighting; Y denotes F, S or I time weighting.

    N denotes a statistical percentile from 1 to 99. Available functions depend on the enabled software modules.

    Exposure Recording and Location

    Parameter Specification
    Dosimeter standard IEC 61252:2002
    Exchange rates 3, 4, 5 and 6 dB
    Selectable threshold 40 to 90 dB
    Selectable criterion level 70 to 90 dB
    Noise dose range 0.01 to 999.99%
    Access control Key lock with restricted access
    Dose parameters LASp, LASMAX, LASMIN, TWA, LEX,8h, LCpeak, LZpeak, LAeq,T, LAVG and DOSE
    Dose logging 1 min intervals; LAVG1m, LAeq1m, LCpeak, LZpeak, LASmax and LASmin
    General data logging Instantaneous Lp, processed Leq and other indices, and frequency-analysis data; contents depend on enabled analyzers
    Logging interval 20 to 2,000 ms in 20 ms steps
    Data transfer Logged data can be exported to PC; compatible saved data files can be opened in Excel
    Audio formats 8,000 samples/s at 8 bits; 48,000 samples/s at 32 bits
    Audio files WAV with calibration information; stored on the inserted SD card
    Maximum recording per file Less than 1 h at 48 kHz; less than 12 h at 8 kHz
    Playback On the instrument or a computer
    SD card connection USB mass-storage access to the SD card after installing the required program
    GPS option Longitude, latitude, altitude and movement speed recorded alongside noise results
    Reverberation-time option Integrated impulse-response method, with the required reverberation-time software; ISO 3382 reference
    Reverberation method Backward integration of the squared impulse response produces the decay curve; requires a suitable impulse sound source

    Reverberation-time measurement is software dependent.

    Select the required analysis, recording and positioning modules when ordering.

    Interfaces and Operating Conditions

    Parameter Specification
    AC output 1.0 V RMS at full scale; 1 kΩ output impedance; 3.5 mm stereo connector
    DC output 20 mV/dB; 1 kΩ output impedance; DB9 connector
    RS232 PC data transfer and mini-printer connection; 4,800, 9,600 or 115,200 bps
    USB Driver-free connection; communication-command control
    Power supply Four LR6 alkaline or rechargeable batteries; 5 V external supply
    Battery life Up to 30 h with four LR6 alkaline batteries
    Clock accuracy Error <1 min/month
    Operating temperature -10 to +50 °C
    Storage temperature -20 to +70 °C
    Relative humidity 25 to 90%
    EMC category Type X
    Printing Compatible with ZAH58F or ZAH40 mini-printer
    Bluetooth Wireless printing and smartphone communication for remote instrument control
    Dimensions 260 H × 80 W × 30 D mm
    Weight 0.35 kg including batteries
    Related Products
    ZAWA5636-4 Class 2 Sound Level Meter
    A compact sound level meter with noise exposure functions for workplace and environmental measurements.
    ZAWA5688 Class 2 Sound Level Meter
    A modular handheld instrument for environmental and industrial noise surveys, workplace noise assessments, boundary measurements and impulse or peak noise testing.
    PTM300-DUAL Dual-Channel Portable GC
    Two independent precision chromatographic channels support rapid on-site analysis of complex VOC mixtures.
    PTM300 Portable Gas Chromatograph
    A portable GC with a sensitive PID and controlled column temperature for ppb-level detection without sample preconcentration.
    AD310-STS Gas Dilution and Humidity System
    An integrated industrial calibration platform combining thermal mass-flow control, multistage dilution and a two-stage split-flow humidity generator.
    AD310L Standard Gas Generator
    A stationary laboratory system for precise dynamic generation of standard gases.
    AD310MMulti-Channel Gas Dilution Calibrator
    An industrial gas-mixing and dilution platform combining an embedded industrial computer with precision mass-flow controllers.
    AD310C Sonic-Nozzle Gas Dilution Calibrator
    A trace-organic-gas dilution platform based on sonic-nozzle flow control, temperature stabilization and inert flow paths.
    Now let's talk about the product you want.
    rainy@hiyipro.com
    +86-15699785629
    Lisa Niu
    We aim to be a trusted long-term partner for organizations that need dependable gas detection, air-quality monitoring, VOC monitoring, and emissions-monitoring solutions.
    Contact Us
    Contact Person: Lisa Niu
    Phone Number: +86-15699785629
    WhatsApp: +86-15699785629
    Company Address: Room 19B, 17th Floor, Building 1, No. 48 Dongzhimenwai Avenue, Dongcheng District, Beijing
    Copyright © 2026 Zetron Technology - www.multigas-detector.com | Sitemap | Privacy Policy
    Customer service
    detect