loading

Zetron Technology - Environmental Monitoring Instruments & Gas Detection Solutions.


MIC100OZ Online UV Ozone Gas Analyzer for Ozone Generator Monitoring 1
MIC100OZ Online UV Ozone Gas Analyzer for Ozone Generator Monitoring 1

MIC100OZ Online UV Ozone Gas Analyzer for Ozone Generator Monitoring

Zetron MIC100OZ online ozone gas analyzer for ozone generator monitoring, exhaust gas detection, and industrial O₃ concentration measurement. Get a quote.

Detection principle: Dual path ultraviolet light absorption method, using imported ultraviolet LED light source, can be used for detecting the concentration of ozone produced by the outlet gas of the ozone generator or the concentration of ozone in the exhaust gas (dehumidification device needs to be configured), and can run online in real-time 24 hours a day.
Measurement range: 0-300g/Nm3; 0-200g/Nm3;0-100g/Nm3;0-50g/Nm3; 0-1000ppm。
Display resolution: 0.01g/Nm3;
Gas flow rate: 0.3L-0.7L/min;
Input pressure:<0.1MPa;
Concentration error: ≤0.5% FS;
Linear error: ≤0.5% FS;
Dimensions: 350mm (height) x 270mm (width) x 150mm (depth);
Sampling method: positive pressure sampling, negative pressure sampling (optional);
5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Product Description

    The MIC100OZ, developed by Zetron, is an online UV ozone gas analyzer. It utilizes a dual-optical-path UV light source system combined with an intelligent UV LED management system, allowing the device to reach an operational measurement state within approximately one minute of startup. Its design—featuring an independent gas chamber and optical cell—ensures a leak-proof, pressure-resistant structure capable of handling high-flow ozone gas, making it ideal for monitoring ozone concentrations at the outlets of ozone generators or within exhaust gas streams.


    The analyzer includes an automatic zero-adjustment function that calibrates the zero point based on fluctuations in UV LED brightness, thereby enhancing the stability and accuracy of long-term measurements. Designed for continuous, 24-hour operation, it is primarily used to measure ozone concentrations in the output gas of ozone generators or in exhaust gases.


    The MIC100OZ is suitable for a wide range of sectors, including ozone generator manufacturing, municipal water treatment, industrial wastewater management, fine chemical production, food and drinking water processing, space disinfection, and swimming pool sanitation. It can be effectively employed to measure ozone concentrations at the outlets of ozone generators and to determine ozone production output.

    Features

    Product features: Waterproof and dustproof instrument housing, suitable for outdoor installation and use, protection level IP65, equipped with waterproof power and signal aviation connectors. This ozone gas concentration analyzer has a zero point automatic adjustment function, which can automatically adjust the brightness of the ultraviolet LED light source based on the reference light data for zero point calibration without ozone gas. The internal PID adjusts the zero point within a certain range of values.


    This ozone gas concentration analyzer is equipped with a built-in zero calibration device, which can automatically calibrate the zero point according to the user's set time. It can also perform zero point calibration when ozone gas is introduced to ensure the stability of the zero point. This automatic zero calibration process is our company's invention patent. This wall mounted ozone gas concentration analyzer can operate continuously for 24 hours without stopping, mainly used for detecting the ozone concentration of the gas produced at the outlet of the ozone generator or the ozone concentration of the exhaust gas.


    图片1 (3)
    图片2 (2)

    Technical Parameter

    • Measurement range: 0-300g/Nm3
    • Optional range: 0-200g/Nm3, 0-100g/Nm3, 0-50g/Nm3
    • Light source lifespan: approximately 50000 hours (can be used for 4-5 years);
    • Sampling method: positive pressure sampling, negative pressure sampling (optional);
    • Display interface: 7-inch touch screen operation interface;
    • Content interface: Ozone concentration, temperature, pressure;
    • Auxiliary functions: temperature compensation, pressure compensation;
    • Display units: g/Nm3, mg/NL,%WTAir,%WTO2 optional;
    • Display resolution: 0.01g/Nm3;
    • Gas flow rate: 0.3L-0.7L/min;
    • Input pressure:<0.1MPa;
    • Concentration error: ≤0.5% FS;

    Technical Parameter

    • Linear error: ≤0.5% FS;
    • Zero drift:<± 0.3% FS;
    • Response time: signal 0.3 seconds, display 0.3 seconds;
    • Environmental temperature: -20~50 ℃;
    • Interface method: quick twist interface (stainless steel);
    • Sampling aperture: Φ 6 (6mm * 4mm);
    • Communication method: RS-485 Modbus RTU;
    • Output mode: 4-20mA (active);
    • Relay signal: high position relay (NO COM NC), low position relay (NO COM NC);
    • Power supply: AC 110-220V;
    • Dimensions: 350mm (height) x 270mm (width) x 150mm (depth);
    • Note: 1mg/L=1g/m3=467PPM;
    • Free warranty: 24 months (for the host sensor);
    • Note: Standard configuration (built-in): flowmeter, ozone exhaust catalyst, intake filter.
    图片3 (2)

    Signal terminal output


    图片4 (3)


    Ozone Applications


    Exhaust and Flue Gas Denitrification

    1. Ozone can oxidize nitrogen monoxide (NO)—which is sparingly soluble in water—into higher-valence nitrogen oxides such as NO₂, N₂O₃, and N₂O₅, which are readily soluble in water.

    2. The equipment features a compact footprint and low operating costs.

    3. It eliminates odors emitted from industrial exhaust gases and municipal wastewater treatment plants.


    图片5 (4)
    图片6 (3)

    Drinking Water

    Treatment

    1. Pre-ozonation enhances precipitation efficiency and prevents the conversion of organic matter into chloroform.


    2. It is particularly effective in eliminating micropollutants and improves the biodegradability of refractory organic substances.


    3. It utilizes an ozone-activated carbon process for the advanced purification of drinking water.


    4. It improves the color and odor of drinking water.


    5. It serves as an alternative to chlorine for drinking water disinfection.


    Municipal Wastewater Reuse

    1.Decolorization

    2. Odor removal


    3. Elimination of bacteria and viruses

    图片7 (2)
    图片8 (2)

    Industrial Wastewater

    1. Enhancing the biodegradability of organic matter
    2. Oxidation of AOX and COD following biological pretreatment
    3. Removal of toxic substances from wastewater
    4. Removal of halides and decolorization of printing and dyeing wastewater
    5. Removal of surfactants and detergents from laundry effluents


    Swimming Pools

    1. Reduce organic matter content
    2. Disinfect and sterilize
    3. Reduce chlorine dosage
    4. Reduce THMs


    图片9 (2)
    图片10 (2)

    Chemical Pharmaceutical Industry

    1. Oxidizing agents in chemical processes
    2. Chemical synthesis in the cosmetics and pharmaceutical industries
    3. Strong COD oxidation
    4. Degradation of toxic components



    Paper Industry

    1. Replace chlorine in the pulp bleaching process.
    2. Prevent the environmental discharge of chlorides.
    3. Enhance paper whiteness.
    图片11 (2)
    图片12 (2)

    Food and Beverages

    1. Disinfection of food and beverages
    2. Disinfection of packaging materials and production lines
    3. Disinfection of water for freshwater and marine aquaculture
    4. Grain storage and food preservation

    Semiconductor Industry

    1. TOC Reduction
    2. Purification of Cooling Water Circulation
    图片13 (2)
    图片14 (2)

    Process Water and Cooling Water

    1. Replaces chloride-based biocides, reducing corrosion rates
    2. Reduces environmental discharge of halides
    3. Minimizes biofouling
    4. Prevents the formation of biofouling films within water circulation systems


    The Necessity of Ozone Concentration Detection


    Ozone is a powerful oxidizing agent possessing strong properties for sterilization, disinfection, bleaching, and odor removal. Consequently, it is widely utilized in applications such as water disinfection, sterilization and purification in food processing, food preservation and storage, medical and healthcare settings, and household disinfection and purification. In the production and application of ozone generators, maintaining a specific ozone concentration is a critical parameter for ensuring effective disinfection and oxidation, conserving energy, and preventing environmental pollution.


    图片15 (2)
    图片16 (2)

    ▶ Calibration of Ozone Generator Output

    The ozone output of a generator constitutes its primary and most fundamental technical specification; furthermore, this output is derived through calculations based on measured ozone concentrations. Strictly speaking, without reliable means to measure ozone concentration, it is impossible to manufacture a compliant product. Currently, instances of exaggerated or fraudulent output claims regarding ozone generators in the market typically manifest as either a complete absence of specified ozone concentration metrics or the provision of inaccurate data.


    ▶ Ozone Application Projects and Equipment Require Ozone Concentration Monitoring

    The ozone generation capacity of an ozone generator is significantly influenced by factors such as the humidity of the air source, the temperature of the cooling water, and the aging of the discharge surfaces; therefore, regular monitoring of ozone concentration is essential. For large-scale ozone systems, it is highly recommended to install high-concentration ozone (gas) detectors within the process flow. Additionally, detectors should be installed to measure the concentration of dissolved ozone in the treated water mixture, as well as the ozone concentration in the discharged tail gas. This comprehensive monitoring ensures that the entire system operates at its optimal performance level.


    While ozone offers numerous benefits to humanity, it is simultaneously a substance that acts as an environmental pollutant. According to my country's Environmental Air Quality Standards (GB3095-1996), the concentration limits for ozone (based on a 1-hour average) are stipulated as follows: the Level I standard is 0.12 mg/m³; the Level II standard is 0.16 mg/m³; and the Level III standard is 0.20 mg/m³. Regarding industrial hygiene standards for ozone, the maximum permissible limit in most countries is 0.1 ppm (0.20 mg/m³). Therefore, when utilizing ozone for disinfection and sterilization, the concentration should not be excessively high; consequently, a higher output capacity for an ozone generator is not necessarily better. For instance, the output capacity of an ozone generator intended for general household indoor sterilization should be approximately 200 mg/h, and ideally should not exceed 400 mg/h. This ensures that after 30 to 60 minutes of ozone sterilization, the residual indoor concentration remains below the limits required by national health standards. It is important to note that individuals with allergic constitutions may experience symptoms—such as skin irritation, respiratory discomfort, coughing, and rhinitis—if exposed for prolonged periods to environments where the ozone concentration exceeds 0.18 mg/m³. Higher concentrations can inflict even greater harm upon the human body.


    Related Products
    Hydrocarbon Monitor/THC Analyser PTM300S Portable GC-FID Analyzer
    The FID total hydrocarbons analyzer PTM300S is a hydrogen flame ionization detector (FID) with electronic flow control. By taking advantage of the fact that FID is only applicable to organic compounds and has corresponding characteristics for all organic compounds, the sample gas directly enters the detector without the need for chromatographic column separation, and the total content of organic compounds in the sample gas can be directly measured.
    MS700-FG Portable Flue Gas Analyzer for Combustion and Emission Testing
    The MS700-FG Intelligent Portable Flue Gas Analyzer is a state-of-the-art device designed for accurate and efficient measurement of flue gas emissions in various industrial applications. Featuring advanced sensors and a user-friendly interface, it provides real-time data to help ensure compliance with environmental regulations and optimize combustion processes.
    DOAS-1000 UV Emissions 20Gas Analyzer for Industrial Emission Monitoring
    DOAS-1000 Emissions Gas Analyzer is designed for continuous measurement of multiple air pollutants released from industrial combustion systems, production facilities, and stationary emission sources. Using UV-DOAS technology for SO₂ and NOx measurement, with optional NDIR integration for CO and CO₂, it provides reliable multi-component emission analysis.
    U8 Mobile Natural Gas Leak Detection System for Pipeline Inspection
    Trace gas measurements with geolocated survey records
    METHANE + ETHANE ANALYSIS
    WIND-ASSISTED LOCALIZATION
    U8 Mobile Natural Gas Leak Detection System for Pipeline Inspection
    Trace gas measurements with geolocated survey records
    METHANE + ETHANE ANALYSIS
    WIND-ASSISTED LOCALIZATION
    MIC500OZ Wall-Mounted UV Ozone Gas Analyzer for Ozone Generator Monitoring
    Detection principle: Dual path ultraviolet light absorption method, using imported ultraviolet LED light source, can be used for detecting the concentration of ozone produced by the outlet gas of the ozone generator or the concentration of ozone in the exhaust gas (dehumidification device needs to be configured), and can run online in real-time 24 hours a day.
    Measurement range: 0-300g/Nm3; 0-200g/Nm3; 0-100g/Nm3; 0-50g/Nm3; 0-1000ppm。
    MIC300OZ UV Ozone Gas Analyzer for Ozone Generator Monitoring
    Measurement features: patented technology with zero point automatic adjustment function, dual path ultraviolet absorption principle, foreign long-life ultraviolet LED light source, continuous operation, ensuring the stability of detection concentration.
    Test method: Dual path UV absorption method, long-life light source system, high measurement accuracy.
    Measurement principle: According to the Lambert Beer law, accurate measurements are made through the principle of photometric absorption.
    MIC-A01 Oxygen Gas Analyzer for Industrial Process Monitoring
    • 320 x 240 dot-matrix LCD with a standard 19-inch rack-mount chassis for integration into complete gas analysis systems.
    • Uses an imported laser sensor together with microcontroller technology for industrial gas analysis.
    • Designed for rapid oxygen-content analysis in a wide range of chemical processes.
    • Supports 4-20 mA output and RS232/RS485 communication with
    Modbus RTU.
    Now let's talk about the product you want.
    O3@bjzetron.com
    +86-15699785629
    Lisa Niu
    We aim to be a trusted long-term partner for organizations that need dependable gas detection, air-quality monitoring, VOC monitoring, and emissions-monitoring solutions.
    Contact Us
    Contact Person: Lisa Niu
    Phone Number: +86-15699785629
    WhatsApp: +86-15699785629
    Company Address: Room 19B, 17th Floor, Building 1, No. 48 Dongzhimenwai Avenue, Dongcheng District, Beijing
    Copyright © 2026 Zetron Technology - www.multigas-detector.com | Sitemap | Privacy Policy