loading

Zetron Technology - Environmental Monitoring Instruments & Gas Detection Solutions.


MIC500OZ Wall-Mounted UV Ozone Gas Analyzer for Ozone Generator Monitoring 1
MIC500OZ Wall-Mounted UV Ozone Gas Analyzer for Ozone Generator Monitoring 1

MIC500OZ Wall-Mounted UV Ozone Gas Analyzer for Ozone Generator Monitoring

  • Detection principle: Dual path ultraviolet light absorption method, using imported ultraviolet LED light source, can be used for detecting the concentration of ozone produced by the outlet gas of the ozone generator or the concentration of ozone in the exhaust gas (dehumidification device needs to be configured), and can run online in real-time 24 hours a day.
  • Measurement range: 0-300g/Nm3; 0-200g/Nm3; 0-100g/Nm3; 0-50g/Nm3; 0-1000ppm。
5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Features

    Product features: Waterproof and dustproof instrument housing, suitable for outdoor installation and use, protection level IP65, equipped with waterproof power and signal aviation connectors. This ozone gas concentration analyzer has a zero point automatic adjustment function, which can automatically adjust the brightness of the ultraviolet LED light source based on the reference light data for zero point calibration without ozone gas. The internal PID adjusts the zero point within a certain range of values. This ozone gas concentration analyzer is equipped with a built-in zero calibration device, which can automatically calibrate the zero point according to the user's set time. It can also perform zero point calibration when ozone gas is introduced to ensure the stability of the zero point. This automatic zero calibration process is our company's invention patent. This wall mounted ozone gas concentration analyzer can operate continuously for 24 hours without stopping, mainly used for detecting the ozone concentration of the gas produced at the outlet of the ozone generator or the ozone concentration of the exhaust gas.


    图片20 (2)
    图片21 (2)

    Technical Parameter

    • Measurement range: 0-300g/Nm3
    • Optional range: 0-200g/Nm3, 0-100g/Nm3, 0-50g/Nm3, 0-1000ppm
    • Light source method: UV LED light source
    • Light source lifespan: approximately 50000 hours (can be used for 4-5 years)
    • Sampling method: positive pressure sampling, negative pressure sampling (optional)
    • Display interface: 5.0-inch touch screen operation interface (optional 7-inch touch screen)
    • Content interface: Ozone concentration, temperature, pressure
    • Auxiliary functions: temperature compensation, pressure compensation
    • Display units: g/Nm3, mg/NL,%WTAir,%WTO2 optional
    • Display resolution: 0.01g/Nm3
    • Gas flow rate: 0.5L±0.2L/min
    • Input pressure:<0.1MPa
    • Concentration error: ≤0.3% FS

    Technical Parameter

    • Linear error: ≤0.3% FS
    • Zero drift:<0.3% FS
    • Response time: signal<0.03 seconds, display<0.3 seconds
    • Environmental temperature: -20~50 ℃
    • Pipeline interface method: quick twist (stainless steel)
    • Sampling aperture: Φ 6 (6mm * 4mm)
    • Communication method: RS-485 Modbus RTU
    • Output mode: 4-20mA (active)
    • Relay signal: high position relay (NO COM NC), low position relay (NO COM NC)
    • Power supply: AC 110-220V
    • Dimensions: 230mm (height) x 330mm (width) x 150mm (depth)
    • Note: 1mg/L=1g/m3=467PPM
    • Free warranty: 24 months (for the host sensor)
    • Equipped with an automatic zero calibration device, it can also calibrate the zero point when ozone is introduced.
    • Note: Standard configuration (built-in): anti-corrosion flowmeter, ozone exhaust disruptor, ozone intake (dust) filter.
    图片22 (2)


    Parameters


    ▶ Signal terminal output

    (01)RS485+  (MODBUS)

    (03)4-20MA+

    (02)RS485-  (MODBUS)

    (04)4-20MA-

    Related Products
    Hydrocarbon Monitor/THC Analyser PTM300S Portable GC-FID Analyzer
    The FID total hydrocarbons analyzer PTM300S is a hydrogen flame ionization detector (FID) with electronic flow control. By taking advantage of the fact that FID is only applicable to organic compounds and has corresponding characteristics for all organic compounds, the sample gas directly enters the detector without the need for chromatographic column separation, and the total content of organic compounds in the sample gas can be directly measured.
    MS700-FG Portable Flue Gas Analyzer for Combustion and Emission Testing
    The MS700-FG Intelligent Portable Flue Gas Analyzer is a state-of-the-art device designed for accurate and efficient measurement of flue gas emissions in various industrial applications. Featuring advanced sensors and a user-friendly interface, it provides real-time data to help ensure compliance with environmental regulations and optimize combustion processes.
    DOAS-1000 UV Emissions 20Gas Analyzer for Industrial Emission Monitoring
    DOAS-1000 Emissions Gas Analyzer is designed for continuous measurement of multiple air pollutants released from industrial combustion systems, production facilities, and stationary emission sources. Using UV-DOAS technology for SO₂ and NOx measurement, with optional NDIR integration for CO and CO₂, it provides reliable multi-component emission analysis.
    U8 Mobile Natural Gas Leak Detection System for Pipeline Inspection
    Trace gas measurements with geolocated survey records
    METHANE + ETHANE ANALYSIS
    WIND-ASSISTED LOCALIZATION
    U8 Mobile Natural Gas Leak Detection System for Pipeline Inspection
    Trace gas measurements with geolocated survey records
    METHANE + ETHANE ANALYSIS
    WIND-ASSISTED LOCALIZATION
    MIC100OZ Online UV Ozone Gas Analyzer for Ozone Generator Monitoring
    Detection principle: Dual path ultraviolet light absorption method, using imported ultraviolet LED light source, can be used for detecting the concentration of ozone produced by the outlet gas of the ozone generator or the concentration of ozone in the exhaust gas (dehumidification device needs to be configured), and can run online in real-time 24 hours a day.
    Measurement range: 0-300g/Nm3; 0-200g/Nm3; 0-100g/Nm3; 0-50g/Nm3; 0-1000ppm。
    MIC300OZ UV Ozone Gas Analyzer for Ozone Generator Monitoring
    Measurement features: patented technology with zero point automatic adjustment function, dual path ultraviolet absorption principle, foreign long-life ultraviolet LED light source, continuous operation, ensuring the stability of detection concentration.
    Test method: Dual path UV absorption method, long-life light source system, high measurement accuracy.
    Measurement principle: According to the Lambert Beer law, accurate measurements are made through the principle of photometric absorption.
    MIC-A01 Oxygen Gas Analyzer for Industrial Process Monitoring
    • 320 x 240 dot-matrix LCD with a standard 19-inch rack-mount chassis for integration into complete gas analysis systems.
    • Uses an imported laser sensor together with microcontroller technology for industrial gas analysis.
    • Designed for rapid oxygen-content analysis in a wide range of chemical processes.
    • Supports 4-20 mA output and RS232/RS485 communication with
    Modbus RTU.
    Now let's talk about the product you want.
    O3@bjzetron.com
    +86-15699785629
    Lisa Niu
    We aim to be a trusted long-term partner for organizations that need dependable gas detection, air-quality monitoring, VOC monitoring, and emissions-monitoring solutions.
    Contact Us
    Contact Person: Lisa Niu
    Phone Number: +86-15699785629
    WhatsApp: +86-15699785629
    Company Address: Room 19B, 17th Floor, Building 1, No. 48 Dongzhimenwai Avenue, Dongcheng District, Beijing
    Copyright © 2026 Zetron Technology - www.multigas-detector.com | Sitemap | Privacy Policy
    Customer service