All Products
-
Portable Multi Gas Detector
-
Portable Single Gas Detector
-
Personal Gas Detector
-
Fixed Gas Detector
-
Flue Gas Analyzer
-
Air Quality Monitoring Stations
-
Exhaust Gas Analyzer
-
Airborne Particle Counter
-
Laser Methane Detector
-
Online Infrared Syngas Analyzer
-
Open Path Infrared Gas Detector
-
Household Gas Alarm
-
Indoor Air Quality Monitors
-
Gas Detection Controller
-
Gas Detector Accessories
-
Integrity Test Machine
-
Compressed Air Quality And Purity Instruments
-
Gas Detector Sensor
-
DoraHello, I already used the equipment in an aluminum smelting plant in Mexico and I was surprised by the function of your company's laser device.
-
SylviaGood gas leak detection instrument !!! High accurate test values :D
Contact Person :
Lisa Niu
Phone Number :
+86 15699785629
Whatsapp :
+8615699785629
Zetron HSP12 Flue Gas Analyser Probe Tmax 1000 Degree Standard For Industrial Engines
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Details
Type | Sampling Probe | Model Number | PTM600-Bio |
---|---|---|---|
Function | Pressure & Temperature Function | Length | 1200mm Probe + 1000mm Cooling Hose |
Detecting Gas | Flue Gas | Built-in Filter | Water & Dust Filter |
Place Of Origin | Beijing, China | Warranty | 12 Months |
Highlight | 1000 degree flue gas analyser probe,industrial engines flue gas analyser probe,1000 degree flue gas probe |
Product Description
Sampling Probe 1200℃ for Flue Gas Analyzer
OVERVIEW
PTM600-FG flue gas detector can optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 1200 ℃.
1200mm & 1000 ℃ probe, 1000mm cooling hose, with water & dust filter, with pressure & temperature function.
SPECIFICATION
Gases to be detected
|
Range
|
Accurancy
|
Resolution
|
Response time T90
|
Combustible gas ( EX )
|
0-100%LEL
|
<±2%(F.S)
|
0.1%LEL
|
≤10 seconds
|
Methane ( CH4 )
|
0-100%Vol
|
<±2%(F.S)
|
0.1%Vol
|
≤10 seconds
|
Oxygen gas ( O2 )
|
0-30%Vol
|
<±2%(F.S)
|
0.01%Vol
|
≤10 seconds
|
Hydrogen sulfide ( H2S )
|
0-100ppm
|
<±2%(F.S)
|
0.01ppm
|
≤30 seconds
|
Sulfur dioxide ( SO2 )
|
0-100ppm
|
<±2%(F.S)
|
0.01ppm
|
≤30 seconds
|
Nitric oxide ( NO )
|
0-100ppm
|
<±2%(F.S)
|
0.01ppm
|
≤30 seconds
|
Ethylene oxide ( ETO )
|
0-100ppm
|
<±2%(F.S)
|
0.01ppm
|
≤30 seconds
|
Phosgene ( COCL2 )
|
0-1ppm
|
<±2%(F.S)
|
0.001ppm
|
≤20 seconds
|
Silane ( SiH4 )
|
0-50ppm
|
<±2%(F.S)
|
0.01ppm
|
≤30 seconds
|
APPLICATION SCENES
Petroleum, chemical, pharmaceutical, environmental protection, gas distribution, flue gas analysis, air treatment and all other occasions that need to detect and analyze gas concentration.