• Beijing Zetron Technology Co., Ltd
    Dora
    Hello, I already used the equipment in an aluminum smelting plant in Mexico and I was surprised by the function of your company's laser device.
  • Beijing Zetron Technology Co., Ltd
    Sylvia
    Good gas leak detection instrument !!! High accurate test values :D
Contact Person : Lisa Niu
Phone Number : +86 15699785629
Whatsapp : +8615699785629

Zetron THSP1 Exhaust Gas Analyser Probe Air High Temperature 1300 Degrees Measurements

Place of Origin China
Brand Name Zetron
Certification CE, ISO13485, ISO9001
Model Number THSP1
Minimum Order Quantity 1
Packaging Details paper carton
Delivery Time 3-7 days
Payment Terms T/T, L/C, Western Union, MoneyGram
Supply Ability 1000 set/month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Type Sampling Probe Model Number THSP1
Function Pressure & Temperature Function Length 1000mm Probe + 2000mm Cooling Hose
Detecting Gas Flue Gas Built-in Filter Water & Dust Filter
Place Of Origin Beijing, China Warranty 12 Months
High Light

sampling exhaust gas analyser probe

,

1300 degree exhaust gas analyser probe

,

1300 degree flue gas analyser probe

Leave a Message
Product Description
High-temperature 1300℃ Probe for Flue Gas Analyzer
 
OVERVIEW
 
PTM600-FG flue gas detector can optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 1300 ℃.
1000mm & 1300 ℃ probe, 2000mm cooling hose, with water & dust filter, with pressure & temperature function.

 

SPECIFICATION

 

Gases to be detected
Range
Accurancy
Resolution
Response time T90
Combustible gas ( EX )
0-100%LEL
<±2%(F.S)
0.1%LEL
≤10 seconds
Methane ( CH4 )
0-100%Vol
<±2%(F.S)
0.1%Vol
≤10 seconds
Oxygen gas ( O2 )
0-30%Vol
<±2%(F.S)
0.01%Vol
≤10 seconds
Hydrogen sulfide ( H2S )
0-100ppm
<±2%(F.S)
0.01ppm
≤30 seconds
Sulfur dioxide ( SO2 )
0-100ppm
<±2%(F.S)
0.01ppm
≤30 seconds
Nitric oxide ( NO )
0-100ppm
<±2%(F.S)
0.01ppm
≤30 seconds
Ethylene oxide ( ETO )
0-100ppm
<±2%(F.S)
0.01ppm
≤30 seconds
Phosgene ( COCL2 )
0-1ppm
<±2%(F.S)
0.001ppm
≤20 seconds
Silane ( SiH4 )
0-50ppm
<±2%(F.S)
0.01ppm
≤30 seconds
APPLICATION SCENES
 
Petroleum, chemical, pharmaceutical, environmental protection, gas distribution, flue gas analysis, air treatment and all other occasions that need to detect and analyze gas concentration.
 
Zetron THSP1 Exhaust Gas Analyser Probe Air High Temperature 1300 Degrees Measurements 0