-
Portable Multi Gas Detector
-
Portable Single Gas Detector
-
Personal Gas Detector
-
Fixed Gas Detector
-
Flue Gas Analyzer
-
Air Quality Monitoring Stations
-
Exhaust Gas Analyzer
-
Airborne Particle Counter
-
Laser Methane Detector
-
Online Infrared Syngas Analyzer
-
Open Path Infrared Gas Detector
-
Household Gas Alarm
-
Indoor Air Quality Monitors
-
Gas Detection Controller
-
Gas Detector Accessories
-
Integrity Test Machine
-
Compressed Air Quality And Purity Instruments
-
DoraHello, I already used the equipment in an aluminum smelting plant in Mexico and I was surprised by the function of your company's laser device.
-
SylviaGood gas leak detection instrument !!! High accurate test values :D
ODM OBM Multi Gas Leak Detector 18 in 1 Portable Gas Monitor
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | Portable Gas Detector | Type | Portable Multi Gas Anlyzer, Built-in Pump |
---|---|---|---|
Function | Measure Gas Purity | Sensor Type | Infrared Sensors Imported |
Detecting Gas | Combustible Gas/H2S/CO/O2/H2S/H2 | Connection | Wi-Fi/USB Network |
Customized Support | OEM, ODM, OBM | Weight | 2.5kg |
High Light | ODM Multi Gas Leak Detector,OBM Portable Gas Monitor,OBM Portable Gas Monitor |
Zetron PTM600 Portable Gas Monitor
18 in 1 | Internal Pump | Built-in Printer | Wireless Data Transmission
PTM600 portable gas detector has the function of measuring multi gases, temperature and humidity.
The product is provided with high measurement precision, stable performance and simple operation and convenient to carry.
It is possible to simultaneously detect 1 ~6 types of gases, up to 18 or more types of gases, and the types for detection are more than 500 types.
· Temperature and humidity measurement function
· 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1 meter)
· High temperature sampling and cooling filter handle
· High temperature humidity pretreatment system· External remote sampling pump
· Multiple humidity dust filter· CD-ROM (upper level computer communication software)
· SD card storage
· USB disk storage
· External mini wireless infrared printer
· Built-in mini printer
· Wireless data communications: RS232, infrared communication, automatic recognition
Gases to be detected | Arbitrary combination of 1 ~ 6 types of gases which can be expanded to 18 or more types of gases, such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on. Optional configuration: temperature and humidity measurements. |
||||
Application scenarios | All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on. |
||||
Detection range | 0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized. | ||||
Resolution | 0.01ppm or 0.001ppm (0 ~ 10 ppm); 0.01ppm (0 ~ 100 ppm), 0.1ppm (0 ~ 1000 ppm), 1ppm (0 ~ 10000 ppm or more), 0.01 mg/l (0 ~ 200 mg/l), 0.1% LEL, 0.01%, 0.001% Vol |
||||
Detection principle | Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand. | ||||
Sensor service life | Electrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 ~ 10 years; catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years. |
||||
Allowable error | ≤±2% F.S (other or higher precision levels can be customized) | ||||
Linearity | ≤±2% | Repeatability | ≤±2% | Uncertainty | ≤±2% |
Response time | T90≤20 seconds | Recovery time | ≤30 seconds | ||
Working environment | Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH, and built-in filters can be used in high humidity or high dust environment. | ||||
Sample gas temperature | -40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 1300 ℃. | ||||
Temperature and humidity measurement | Optional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 100% RH, precision level at 3 % RH | ||||
Power supply | 3.6VDC, 10000mA high capacity rechargeable polymer battery | ||||
Display mode | 3.5-inch high-definition color screen | ||||
Detection mode | Built-in pump-suction type measurement, and flow rate at 800 ml / min. Calibration flow rate should be greater than 800 ml / min, three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass |
||||
Alarm mode | It is possible to set as sound & light alarm, vibration alarm, turning off the alarm. | ||||
Communication interface | USB (charging and communication), optional: RS232, infrared communication, automatic recognition | ||||
Data storage | Standard configuration is the data storage capacity for 100, 000 entries; SD card storage and USB disk storage functions are optional configuration. | ||||
Protection level | IP66 | ||||
Explosion-proof type | Intrinsically safe type | ||||
Explosion-proof mark | Exia II CT6 | ||||
Exterior dimensions | 230×210×120 mm (L×H×W) | ||||
Weight | 2.5Kg | ||||
Standard accessories | Manual, qualification certificate, warranty card, USB charger (including the data cable), high-grade aluminum instrument case, built-in humidity dust filter, 0.4 meter stainless steel sampling handle (1 meter of hose, with dust filter, not retractable) |
||||
Optional items |
Temperature and humidity measurement function, 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1meter), external remote sampling pump, high temperature sampling and cooling filter handle, high temperature humidity pretreatment system, CD-ROM (upper level computer communication software), external mini wireless infrared printer, built-in mini printer, SD card storage, USB disk storage, wireless data communications.
|
All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.