Portable Multi Gas Detector
-
Portable Single Gas Detector
-
Personal Gas Detector
-
Fixed Gas Detector
-
Flue Gas Analyzer
-
Air Quality Monitoring Stations
-
Exhaust Gas Analyzer
-
Airborne Particle Counter
-
Laser Methane Detector
-
Online Infrared Syngas Analyzer
-
Open Path Infrared Gas Detector
-
Household Gas Alarm
-
Indoor Air Quality Monitors
-
Gas Detection Controller
-
Gas Detector Accessories
-
Integrity Test Machine
-
Compressed Air Quality And Purity Instruments
-
DoraHello, I already used the equipment in an aluminum smelting plant in Mexico and I was surprised by the function of your company's laser device.
-
SylviaGood gas leak detection instrument !!! High accurate test values :D
86-108 kРа Flue Gas Analyzer CH4 CO2 H2S O2 Online Biogas Analyzer
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xMeasurement Component | CH4 CO2 H2S O2 | Inlet Pressure | 2kPa-50kPa |
---|---|---|---|
Gas Flow | 0.7-1.2L / Min | Work Temperature | -15℃ To + 45℃ |
Size | 400*485*132mm | Weight | 18kg |
High Light | 108kРа Flue Gas Analyzer,Online Flue Gas Analyzer,Online Biogas Analyzer |
Online Biogas Analyzer
Gasboard-3200 online biogas analyzer is designed to measure CH4, CO2, H2S and O2 concentration simultaneously in different biogas applications, like landfill, water treatment, CDM projects, anaerobic digestion and other fermentation processes, based on NDIR technology for CH4 ,CO2 gases and ECD technology for H2S and O2 gases.
• Measures CO2, CH4, O2, H2S gases with customized measure range
• 4-20mA output and RS232 communication are available
• Modular sensor design ensures easy on operation and maintenance
• Self-developed gas conditioning device to remove vapor and dust in biogas for analyzer’s protection in long term operation
• Programmable auto-zero function to ensure better and stable measuring accuracy.
General Parameter | |
Measurement | CO2, CH4, H2S, O2 |
Technology | CO2,H2(NDIR) |
H2S.O2(ECD) | |
Range | CO2 0-50%, CH4 0-100%, H2S 0-9999ppm,O2 0-25% |
Measurement range can be customized | |
Resolution | CO2. CH4,O2 0.01% H2S 1ppm |
Precision | CO2. CH4 ≤1% FS |
H2S, O2 ≤2% FS | |
Flow | 0.7-1.2 L/min |
Inlet pressure | 2KPa-50KPa |
Sampling gas condition | no water vapor, no dust, no tar |
Response time(T90) | <10s (NDIR) |
Working Environment | |
Working temperature | 0 to 50 ℃ |
Relative humidity | ≤95% non condensing |
Ambient pressure | 86-108 kРа |
Dimensions | |
Size | 400mm(L)*485mm(W)*132mm(H) |
Weight | 18kg |
Biogas plants, landfill sites, water treatment, sludge digestion, bio-methane production, CDM project ,anaerobic digestion and other fermentation processes.