PTM600 Portable Multi Gas Detector 18 In 1 With Lager LCD Display Screen

Place of Origin China
Brand Name Zetron
Certification CE
Model Number PTM600
Minimum Order Quantity 1 set
Price USD 890/set - 7298/set
Packaging Details 230x210x120 mm
Delivery Time 1-10 work days
Payment Terms T/T, Western Union, MoneyGram, D/P, D/A, L/C
Supply Ability 1000 SET / week

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Product Name Portable Gas Detector Type Portable Multi Gas Anlyzer, Built-in Pump
Sensor Type Infrared Sensors Imported Detecting Gas Combustible Gas/H2S/CO/O2/H2S/H2
Customized Support OEM, ODM, OBM Response Time T90≤20 Seconds
Repeatability ≤±2% Weight 2.5kg
High Light

LCD Portable Multi Gas Detector

,

PTM600 Portable Multi Gas Detector

,

Portable H2S Gas Detector

Leave a Message
Product Description

Zetron PTM600 Portable Gas Detector


18 in 1 | Internal Pump | Built-in Printer | Wireless Data Transmission

 

OVERVIEW


PTM600 portable gas detector has the function of measuring multi gases, temperature and humidity.


The product is provided with high measurement precision, stable performance and simple operation and convenient to carry.
It is possible to simultaneously detect 1 ~6 types of gases, up to 18 or more types of gases, and the types for detection are more than 500 types.

 

18 in 1 Multi Gas Detector 0

 

FEATURES & BENEFITS

 

1. Fast and Effecient Gas Detection

  • It is possible to simultaneously detect 1 ~ 6 types of gases, which can be expanded to 18 or more, and the types for detection are more than 500 types. 
  • There are 7 gas units to display, and the units can be switched freely. Units that can be selected: PPM, mg/m3, Vol%, LEL%, PPHM, ppb, mg/l.
     

2. Richa Human-machine Interface

  • 3.5-inch high-definition color screen, display the information such as real-time concentration, 
  • Graphical display, and use the form of curve to reflect the trend of gas concentration changes in a certain period of time.
  • Simultaneously display the concentrations of five types of gases, repeatedly display the concentration of single-channel gases in large font, and display the real-time curve. And it is possible to switch among three display modes.
     

3. Multi Gas Detection Mode and Large Data Storage

  • Standard configuration is the data storage capacity for 100, 000 entries; real-time storage and fixed time storage are supported, or only the data of the alarm concentration will be stored. Large capacity can be customized.
  • It is supported to use the local host to view, and delete data, and upload the data via USB, RS232 interface or infrared communication to the computer for data analysis or printing.
     

4. Multi Alarm Modes and Data Logging Function

  • 0.4 meter stainless steel sampling handle (with dust filter, not retractable) ,preliminary treatment of the detection gas, so as to protect the equipment.
  • Multiple alarm modes, and multi-directional and three-dimensional indication alarm states.Alarm types include: concentration alarm, under-voltage alarm, and failure alarm.
  • Multiple alarm mode settings: low alarm, high alarm, interval alarm, and weighted average alarm.
  • Zero-point automatic tracking; long-term use will not be affected by the zero drift.
  • Data recovery function; in case of mis-operation, it is possible to select partial or full recovery.
  • Mis-operation recognition function: automatic recognition and prevention of the concentration calibration mis-operation, which is possible to avoid the poor performance that may be caused by human factors.
     

5. Temperature and humidity measurement function

  • 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1 meter)
  • Multiple humidity dust filter· CD-ROM (upper level computer communication software)
  • SD card storage
  • USB disk storage
  • External mini wireless infrared printer
  • Built-in mini printer
  • Wireless data communications: RS232, infrared communication, automatic recognition

 

SPECIFICATION

 

Gases to be detected Arbitrary combination of 1 ~ 6 types of gases which can be expanded to 18 or more types of gases, such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on.
Application scenarios All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical,
environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
Detection range

0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized.

Resolution 0.01ppm or 0.001ppm (0 ~ 10 ppm);
0.01ppm (0 ~ 100 ppm),
0.1ppm (0 ~ 1000 ppm),
1ppm (0 ~ 10000 ppm or more),
0.01 mg/l (0 ~ 200 mg/l),
0.1% LEL,
0.01%,
0.001% Vol
Detection principle Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand.
Sensor service life Electrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 ~ 10 years;
catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years.
Allowable error ≤±2% F.S (other or higher precision levels can be customized)
Linearity ≤±2% Repeatability ≤±2% Uncertainty ≤±2%
Response time T90≤20 seconds Recovery time ≤30 seconds
Working environment Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH, and built-in filters can be used in high humidity or high dust environment.
Sample gas temperature -40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 1300 ℃.
Power supply 3.6VDC, 10000mA high capacity rechargeable polymer battery
Display mode 3.5-inch high-definition color screen
Detection mode Built-in pump-suction type measurement, and flow rate at 800 ml / min. Calibration flow rate should be greater than 800 ml / min,
three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass
Alarm mode It is possible to set as sound & light alarm, vibration alarm, turning off the alarm.
Communication interface USB (charging and communication), optional: RS232, infrared communication, automatic recognition
Data storage Standard configuration is the data storage capacity for 100, 000 entries; SD card storage and USB disk storage functions are optional configuration.
Protection level IP66
Explosion-proof type Intrinsically safe type
Explosion-proof mark Exia II CT6
Standard accessories Manual, qualification certificate, warranty card, USB charger (including the data cable), high-grade aluminum instrument case,
built-in humidity dust filter, 0.4 meter stainless steel sampling handle (1 meter of hose, with dust filter, not retractable)
Optional items
Temperature and humidity measurement function, 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1
meter), external remote sampling pump, high temperature sampling and cooling filter handle, high temperature humidity pretreatment
system, CD-ROM (upper level computer communication software), external mini wireless infrared printer, built-in mini printer, SD
card storage, USB disk storage, wireless data communications.

 

 

APPLICATION


All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.

It is suitable for detecting the concentrations of gases in the atmosphere environment in the pipeline or confined space; and the purity of the gas leakage and various high concentration single gases with the background gas as nitrogen gas or oxygen gas.

 

PTM600 Portable Multi Gas Detector 18 In 1 With Lager LCD Display Screen 1

 

FAQ


Q: When do you reply to messages?
A: We will reply you for your inquiry in 24 hours.

Q: When do you send the products? And how do you send it ?
A: For the small order, we will send out the goods with 5 days,If have stock ,we will send immediately.
We send them by ups, fedex, tnt or dhl. For big order, normal is 20 days will finish.

Q:Do you accept OEM or revised logo, color, model,size?
A:Yes, we accept OEM for the qualify buyer. We can make the products according to customer personal requirement.

Q: How about the quality of the managements ?
A: We have a complete quality control system , all of our products will be fully pre-inspection by QC departments before,shipping to you . We have the certification of ISO,CE we could send the certification test of our company to you.

Q: How about your after-sale service?
A: After sending, we will track the products for you , until you get the products.
When you got the goods, test them, and give me a feedback.
If you have any questions about the problem, contact with us, we will offer the solve way for you.