Detector Gas Portable Outdoor Air Quality Tester Gas Analyzer PM1 PM10 PM2.5

Place of Origin China
Brand Name Zetron
Certification CE
Model Number MS600
Minimum Order Quantity 1 set
Price USD 446/set - 1298/set
Packaging Details 195*77*46mm
Delivery Time 1-10 work days
Payment Terms T/T, Western Union, MoneyGram, D/P, D/A, L/C
Supply Ability 1000 SET / week

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Product Name 6 In 1 Gas Analyzer Type Portable Gas Detector
Gas Unit PPM, Mg/m3, Vol%, LEL%, PPHM, Ppb, Mg/l. Function Portable Multi Gas Detector
Color Orange Data Storage 100, 000 Entries
Protection Level IP67 Alarm Mode Audible-visual Alarm,Vibration Alarm,Voice≥75dB@25cm
High Light

PM1 Portable Air Quality Tester

,

PM10 Outdoor Air Quality Tester

,

PM2.5 Outdoor Air Quality Tester

Leave a Message
Product Description

MS600 - Chlorine Dioxide Gas Detector

 

OVERVIEW

 

MS600 it adopted advanced electric circuit design, mature kernel algorithm processing, unique external appearance design, had achieved a number of patents about the software works, external appearance, and so on.

 

6 in 1 Portable Multi Gas Detector 0

 

FEATURES & BENEFITS

 

Detector Gas Portable Outdoor Air Quality Tester Gas Analyzer PM1 PM10 PM2.5 1

 

①It is possible to simultaneously detect 1 ~ 6 types of gases, and the types for detection are more than 500 types. It is suitable for detecting the concentrations of gases in the atmosphere environment in the pipeline or confined space; and the purity of the gas leakage and various high concentration single gases with the background gas as nitrogen gas or oxygen gas.
②There are 7 gas units to display, and the units can be switched freely. Units that can be selected: PPM, mg/m3, Vol%, LEL%, PPHM, ppb, mg/l.

Detector Gas Portable Outdoor Air Quality Tester Gas Analyzer PM1 PM10 PM2.5 2

 

①2.5-inch high-definition color screen, display the information such as real-time concentration, alarm, time, temperature, humidity, storage, and so on
②Graphical display,
③Simultaneously display the concentrations of five types of gases, repeatedly display the concentration of single-channel gases in large font, and display the real-time curve. And it is possible to switch among three display modes.
 
Detector Gas Portable Outdoor Air Quality Tester Gas Analyzer PM1 PM10 PM2.5 3
Detector Gas Portable Outdoor Air Quality Tester Gas Analyzer PM1 PM10 PM2.5 4

 

①Standard configuration is the data storage capacity for 100, 000 entries; real-time storage and fixed time storage are supported, or only the data of the alarm concentration will be stored. Large capacity can be customized.
②It is supported to use the local host to view, and delete data, and upload the data via USB, RS232 interface or infrared communication to the computer for data analysis or printing.
Detector Gas Portable Outdoor Air Quality Tester Gas Analyzer PM1 PM10 PM2.5 5
Detector Gas Portable Outdoor Air Quality Tester Gas Analyzer PM1 PM10 PM2.5 6
Detector Gas Portable Outdoor Air Quality Tester Gas Analyzer PM1 PM10 PM2.5 7

 

①Built-in humidity dust filter, preliminary treatment of the detection gas, so as to protect the equipment.
②Multiple alarm modes, and multi-directional and three-dimensional indication alarm states.
Multiple alarm mode settings: low alarm, high alarm, interval alarm, and weighted average alarm.
③Zero-point automatic tracking; long-term use will not be affected by the zero drift.
④Multi-level calibration for target points, can ensure the linearity and accuracy of the measurements.
⑤Log recording Record the calibration logs, repair logs, failure history, failure countermeasure solutions, sensor service life due reminder, and function of reminder for the time of next concentration calibration.
⑥Data recovery function.
⑦Mis-operation recognition function: automatic recognition and prevention of the concentration calibration mis-operation, which is possible to avoid the poor performance that may be caused by human factors.
Detector Gas Portable Outdoor Air Quality Tester Gas Analyzer PM1 PM10 PM2.5 8

 

· Temperature and humidity measurement function
· 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1 meter)

· 0.4 meter stainless steel sampling handle (with dust filter, not retractable)
· High temperature sampling and cooling filter handle
· High temperature humidity pretreatment system· External remote sampling pump
· Multiple humidity dust filter· CD-ROM (upper level computer communication software)
· SD card storage
· USB disk storage
· External mini wireless infrared printer
· Wireless data communications: RS232, infrared communication, automatic recognition

Detector Gas Portable Outdoor Air Quality Tester Gas Analyzer PM1 PM10 PM2.5 9
Detector Gas Portable Outdoor Air Quality Tester Gas Analyzer PM1 PM10 PM2.5 10
Detector Gas Portable Outdoor Air Quality Tester Gas Analyzer PM1 PM10 PM2.5 11

 

SPECIFICATION

 

Gases to be detected

Arbitrary combination of 1 ~ 6 types of gases such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on.

Optional configuration: temperature and humidity measurements.

Application scenarios All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
Detection range 0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized.
Resolution

0.01ppm or 0.001ppm (0 ~ 10 ppm);

0.01ppm (0 ~ 100 ppm),

0.1ppm (0 ~ 1000 ppm),

1ppm (0 ~ 10000 ppm or more),

0.01 mg/l (0 ~ 200 mg/l),

0.1% LEL,

0.01%,

0.001% Vol

Detection principle Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand.
Sensor service life Electrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 ~ 10 years; catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years.
Allowable error ≤±1% F.S (other precision levels can be customized)
Linearity ≤±1% Repeatability ≤±1% Uncertainty ≤±1%
Response time T90≤20 seconds Recovery time ≤30 seconds
Working environment Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH, and built-in filters can be used in high humidity or high dust environment.
Sample gas temperature -40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 1300 ℃.
Temperature and humidity measurement Optional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 100% RH, precision level at 3 % RH
Power supply 3.6VDC, 6000mA high capacity rechargeable polymer battery
Display mode 2.5-inch high-definition color screen
Detection mode Built-in pump-suction type measurement, and flow rate at 500 ml / min. Calibration flow rate should be greater than 500 ml / min, three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass
Alarm mode It is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, turning off the alarm.
Communication interface USB (charging and communication), optional: RS232, infrared communication, automatic recognition
Data storage Standard configuration is the data storage capacity for 100, 000 entries; SD card storage function is optional configuration
Protection level IP67
Explosion-proof type Intrinsically safe type
Explosion-proof mark Exia II CT6
Exterior dimensions 180×78×33mm (L×W×H)
Weight 350g
Detection mode Built-in pump-suction type measurement, and flow rate at 500 ml / min. Calibration flow rate should be greater than 500 ml / min, three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass
Alarm mode It is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, turning off the alarm.
Communication interface USB (charging and communication), optional: RS232, infrared communication, automatic recognition
Data storage Standard configuration is the data storage capacity for 100, 000 entries; SD card storage function is optional configuration
Protection level IP67
Explosion-proof type Intrinsically safe type
Explosion-proof mark Exia II CT6

 

 

APPLICATION


All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.

 