Portable Multi Gas Detector
-
Portable Single Gas Detector
-
Personal Gas Detector
-
Fixed Gas Detector
-
Flue Gas Analyzer
-
Air Quality Monitoring Stations
-
Exhaust Gas Analyzer
-
Airborne Particle Counter
-
Laser Methane Detector
-
Online Infrared Syngas Analyzer
-
Open Path Infrared Gas Detector
-
Household Gas Alarm
-
Indoor Air Quality Monitors
-
Gas Detection Controller
-
Gas Detector Accessories
-
Integrity Test Machine
-
Compressed Air Quality And Purity Instruments
-
Gas Detector Sensor
-
DoraHello, I already used the equipment in an aluminum smelting plant in Mexico and I was surprised by the function of your company's laser device.
-
SylviaGood gas leak detection instrument !!! High accurate test values :D
Mobile Portable Multi Gas Detector Methane Gas Monitor IP67 With Free Calibration Service

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | 6 In 1 Gas Analyzer | Type | Portable Gas Detector, Portable Gas Detection |
---|---|---|---|
Gas Unit | PPM, Mg/m3, Vol%, LEL%, PPHM | Function | Multi Gas Detector |
Color | Orange | Data Storage | 100, 000 Entries |
Protection Level | IP67 | Alarm Mode | Audible-visual Alarm,Vibration Alarm,Voice≥75dB@25cm |
Exterior Dimensions | 180×78×33mm (L×W×H) | Weight | 350g |
Highlight | MS600 Portable Multi Gas Detector,IP67 Portable Multi Gas Detector,MS600 Methane Gas Monitor |
MS600 Six-In-One Portable Gas Detector
MS600 Series Portable Composite Gas Detector can be used in: mobile rapid and accurate detection of a variety of gas concentration and measurement of environmental temperature and humidity, if the measurement exceeded the limit value, the alarm will sound.
It is possible to simultaneously detect 1 ~ 6 types of gases, and the units can be switched freely. The types for detection are more than 500 types.
①It is possible to simultaneously detect 1 ~ 6 types of gases, and the types for detection are more than 500 types. It is suitable for detecting the concentrations of gases in the atmosphere environment in the pipeline or confined space; and the purity of the gas leakage and various high concentration single gases with the background gas as nitrogen gas or oxygen gas.
②There are 7 gas units to display, and the units can be switched freely. Units that can be selected: PPM, mg/m3, Vol%, LEL%, PPHM, ppb, mg/l.
②Graphical display, and use the form of curve to reflect the trend of gas concentration changes in a certain period of time.
③Simultaneously display the concentrations of five types of gases, repeatedly display the concentration of single-channel gases in large font, and display the real-time curve. And it is possible to switch among three display modes.
②It is supported to use the local host to view, and delete data, and upload the data via USB, RS232 interface or infrared communication to the computer for data analysis or printing.
2. Multiple alarm modes, and multi-directional and three-dimensional indication alarm states. It includes sound & light alarm, vibration alarm, display screen visual alarm.Alarm types include: concentration alarm, under-voltage alarm, and failure alarm.
Multiple alarm mode settings: low alarm, high alarm, interval alarm, and weighted average alarm.
3. Log recording Record the calibration logs, repair logs, failure history, failure countermeasure solutions, sensor service life due reminder, and function of reminder for the time of next concentration calibration.
4. Data recovery function; in case of mis-operation, it is possible to select partial or full recovery.
5. Mis-operation recognition function: automatic recognition and prevention of the concentration calibration mis-operation, which is possible to avoid the poor performance that may be caused by human factors.
· Temperature and humidity measurement function
· 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1 meter)
· 0.4 meter stainless steel sampling handle (with dust filter, not retractable)
· High temperature sampling and cooling filter handle
· High temperature humidity pretreatment system· External remote sampling pump
· Multiple humidity dust filter· CD-ROM (upper level computer communication software)
· SD card storage
· USB disk storage
· External mini wireless infrared printer
· Wireless data communications: RS232, infrared communication, automatic recognition
Gases to be detected |
Arbitrary combination of 1 ~ 6 types of gases such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on. Optional configuration: temperature and humidity measurements. |
|||||
Application scenarios | All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on. | |||||
Detection range | 0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized. | |||||
Resolution |
0.01ppm or 0.001ppm (0 ~ 10 ppm); 0.01ppm (0 ~ 100 ppm), 0.1ppm (0 ~ 1000 ppm), 1ppm (0 ~ 10000 ppm or more), 0.01 mg/l (0 ~ 200 mg/l), 0.1% LEL, 0.01%, 0.001% Vol |
|||||
Detection principle | Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand. | |||||
Sensor service life | Electrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 ~ 10 years; catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years. | |||||
Allowable error | ≤±1% F.S (other precision levels can be customized) | |||||
Linearity | ≤±1% | Repeatability | ≤±1% | Uncertainty | ≤±1% | |
Response time | T90≤20 seconds | Recovery time | ≤30 seconds | |||
Working environment | Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH, and built-in filters can be used in high humidity or high dust environment. | |||||
Temperature and humidity measurement | Optional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 100% RH, precision level at 3 % RH | |||||
Power supply | 3.6VDC, 6000mA high capacity rechargeable polymer battery | |||||
Display mode | 2.5-inch high-definition color screen | |||||
Detection mode | Built-in pump-suction type measurement, and flow rate at 500 ml / min. Calibration flow rate should be greater than 500 ml / min, three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass | |||||
Alarm mode | It is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, turning off the alarm. | |||||
Communication interface | USB (charging and communication), optional: RS232, infrared communication, automatic recognition | |||||
Data storage | Standard configuration is the data storage capacity for 100, 000 entries; SD card storage function is optional configuration | |||||
Protection level | IP67 | |||||
Explosion-proof type | Intrinsically safe type | |||||
Explosion-proof mark | Exia II CT6 | |||||
Exterior dimensions | 180×78×33mm (L×W×H) | |||||
Weight | 350g | |||||
Standard accessories | Manual, qualification certificate, warranty card, USB charger (including the data cable), high-grade aluminum instrument case, belt clip, humidity dust filter | |||||
Optional items | Temperature and humidity measurement function, 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1 meter), 0.4 meter stainless steel sampling handle (with dust filter, not retractable), high temperature sampling and cooling filter handle, high temperature humidity pretreatment system, multiple humidity dust filter, hanging rope, CD-ROM (upper level computer communication software), SD card storage, wireless data communications, external mini wireless infrared printer | |||||
Detection mode | Built-in pump-suction type measurement, and flow rate at 500 ml / min. Calibration flow rate should be greater than 500 ml / min, three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass | |||||
Alarm mode | It is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, turning off the alarm. | |||||
Communication interface | USB (charging and communication), optional: RS232, infrared communication, automatic recognition | |||||
Data storage | Standard configuration is the data storage capacity for 100, 000 entries; SD card storage function is optional configuration | |||||
Protection level | IP67 | |||||
Explosion-proof type | Intrinsically safe type | |||||
Explosion-proof mark | Exia II CT6 |
All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.