0-200Mg/L Ozone O3 Gas Detector Alarm MIC500S Outdoor / Indoor Ultraviolet Sensor
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | Fixed Gas Detector | Model Number | MIC500S |
---|---|---|---|
Display Method | 1.7-inch High-definition Color Screen | Protection Level | IP65 |
Weight | 1.8(kg) | Size | 210*170*85mm (L*H*W) |
High Light | 200Mg/L O3 Gas Detector,MIC500S O3 Gas Detector,200Mg/L Ozone Gas Detector |
MIC500S Fixed Toxic And Harmful Gas Detector
Gases to be detected | Ozone/O3 Gas Detector | ||||
Detection range |
0--1000 ppm 0-- 5000 ppm 0-- 50000ppm 0-- 200mg/L Other ranges can be customized |
||||
Resolution |
0.01ppm or 0.001ppm (0 ~ 10 ppm); 0.001% Vol Other ranges can be customized |
||||
Detection principle |
Ultraviolet sensor Electrochemical, infrared, thermal conductivity, PID photoionization, and so on. Depending on the type of gas, range, field environment and user demand, Sensor can be customized |
||||
Sensor service life |
Electrochemical principle: 2 ~ 3 years; Infrared principle: 5 ~ 10 years; Thermal conductivity: 5 years |
||||
Allowable error | ≤±3% F.S (other or higher precision levels can be customized) | ||||
Linearity | ≤±2% | Repeatability | ≤±2% | Uncertainty | ≤±2% |
Response time | T90≤20 seconds | Recovery time | ≤30 seconds | ||
Working environment | Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH (regular) | ||||
Display method | 1.7-inch high-definition color screen | ||||
Working voltage |
12 ~ 30VDC direct current the standard power supply for a single equipment is 24V, DC stabilized voltage switching power supply of 1A or greater than 1A |
||||
Protection level | IP65 | ||||
Explosion-proof type | Explosion suppression type | ||||
Explosion-proof mark | ExdⅡCT6, certificate number: CNEx15.1283 |
■Integrated sound & light alarming device, split-type sound & light alarming device,
■Wireless transmission
①It is possible to transfer data wirelessly to the cell phone, remote monitoring center,
monitoring computers and other monitoring equipment, which will utilize the upper-level host to realize
the functions of data analysis, storage, printing, or the like on the computer.
■ Pretreatment system
①Room temperature and high humidity pretreatment system
②High temperature and high humidity pretreatment system
■Accessory for connection with a computer for monitoring
①Free upper-level host software, RS485 / RS232 converter
②For laptops without RS232 interface, USB / RS232 converting and connecting cable is needed,
All the cases require the fixed installation, and online detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.