Portable Multi Gas Detector
-
Portable Single Gas Detector
-
Personal Gas Detector
-
Fixed Gas Detector
-
Flue Gas Analyzer
-
Air Quality Monitoring Stations
-
Exhaust Gas Analyzer
-
Airborne Particle Counter
-
Laser Methane Detector
-
Online Infrared Syngas Analyzer
-
Open Path Infrared Gas Detector
-
Household Gas Alarm
-
Indoor Air Quality Monitors
-
Gas Detection Controller
-
Gas Detector Accessories
-
Integrity Test Machine
-
Compressed Air Quality And Purity Instruments
-
Gas Detector Sensor
-
DoraHello, I already used the equipment in an aluminum smelting plant in Mexico and I was surprised by the function of your company's laser device.
-
SylviaGood gas leak detection instrument !!! High accurate test values :D
2.5 Inch IP67 Portable Multi Gas Monitor Zetron MS600 Humanized
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | Portable Handheld Gas Detector 6 In 1 O2/H2S/CO/CH4/H2/LEL Gas Analyzer | Model Number | MS600 |
---|---|---|---|
Gas Unit | PPM, Mg/m3, Vol%, LEL%, PPHM | Function | Portable Combustible Analyzer |
Data Storage | 100, 000 Entries | Protection Level | IP67 |
Alarm Mode | Audible-visual Alarm,Vibration Alarm,Voice≥75dB@25cm | Exterior Dimensions | 180×78×33mm (L×W×H) |
Weight | 350g | Screen Size | 2.5 Inch |
Highlight | 2.5 inch portable multi gas monitor,humanized portable multi gas monitor |
MS600 Portable 6 Gas Detector
MS600 Series Portable Composite Gas Detector can be used in: mobile rapid and accurate detection of a variety of gas concentration and measurement of environmental temperature and humidity, if the measurement exceeded the limit value, the alarm will sound.
It is possible to simultaneously detect 1 ~ 6 types of gases, and the units can be switched freely. The types for detection are more than 500 types.
Gases to be detected | Range | Accurancy | Resolution | Response time T90 |
Tetrahydrothiophene ( THT ) | 0-100mg/m3 | <±2%(F.S) | 0.01 mg/ m3 | ≤60 seconds |
Bromine gas ( Br2 ) | 0-10ppm | <±2%(F.S) | 0.001ppm | ≤30 seconds |
Ethyne ( C2 H2 ) | 0-100%LEL | <±2%(F.S) | 0.1%LEL | ≤30 seconds |
Ethylene ( C2 H4 ) | 0-100%LEL | <±2%(F.S) | 0.1%LEL | ≤30 seconds |
Acetaldehyde | 0-10ppm | <±2%(F.S) | 0.01ppm | ≤30 seconds |
Ethanol ( C2 H6O ) | 0-100ppm | <±2%(F.S) | 0.01ppm | ≤30 seconds |
Methanol ( CH4O ) | 0-100ppm | <±2%(F.S) | 0.01ppm | ≤30 seconds |
Carbon disulfide ( CS2 ) | 0-50ppm | <±2%(F.S) | 0.01ppm | ≤30 seconds |
Acrylonitrile ( C3H3N ) | 0-50ppm | <±2%(F.S) | 0.01ppm | ≤30 seconds |
Note: Not all gases and range are listed, if you need more information, please contact us.
②There are 7 gas units to display, and the units can be switched freely. Units that can be selected: PPM, mg/m3, Vol%, LEL%, PPHM, ppb, mg/l.
②Graphical display, and use the form of curve to reflect the trend of gas concentration changes in a certain period of time.
③Simultaneously display the concentrations of five types of gases, repeatedly display the concentration of single-channel gases in large font, and display the real-time curve. And it is possible to switch among three display modes.
②It is supported to use the local host to view, and delete data, and upload the data via USB, RS232 interface or infrared communication to the computer for data analysis or printing.
②Multiple alarm modes, and multi-directional and three-dimensional indication alarm states. It includes sound & light alarm, vibration alarm, display screen visual alarm.Alarm types include: concentration alarm, under-voltage alarm, and failure alarm.
Multiple alarm mode settings: low alarm, high alarm, interval alarm, and weighted average alarm.
③Log recording Record the calibration logs, repair logs, failure history, failure countermeasure solutions, sensor service life due reminder, and function of reminder for the time of next concentration calibration.
④Data recovery function; in case of mis-operation, it is possible to select partial or full recovery.
⑤Mis-operation recognition function: automatic recognition and prevention of the concentration calibration mis-operation, which is possible to avoid the poor performance that may be caused by human factors.
5. Muktiple optional functions, meet the personalized needs
①Temperature and humidity measurement function
②1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1 meter)
③0.4 meter stainless steel sampling handle (with dust filter, not retractable)
④High temperature sampling and cooling filter handle
⑤High temperature humidity pretreatment system· External remote sampling pump
⑥Multiple humidity dust filter· CD-ROM (upper level computer communication software)
⑦SD card storage
⑧USB disk storage
⑨External mini wireless infrared printer
⑩Wireless data communications: RS232, infrared communication, automatic recognition
All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.