Zetron UVOZ-3000 New Rack Type Ozone Analyzer Automatic Concentration Analyzer Imported Sensor

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | Ozone Analyzer | Model Number | UVOZ-3000 |
---|---|---|---|
Display Interface | 4.3 Inch Touch Screen Operation Interface | Auxiliary Functions | Concentration&temperature & Pressure Compensation |
Display Unit | G/Nm3 Mg/NL %WT Ppm Mg/Nm3 | Input Pressure | <0.1MPa |
Zero Point Drift | <±0.8%.FS | Input Power | AC 110-220V. |
Instrument Size | 133mm (height) 482mm (width) 300mm (deep), 19-inch 3U Chassis; (Note 1 Mg/L = 1 G/m3 = 467 PPM) | ||
Highlight | Rack-Type Zetron UVOZ-3000 Ozone Analyzer,New Rack Type Ozone Analyzer |
UVOZ-3000 Ozone Detector
The primary purpose of this ozone gas concentration analyzer is to measure and analyze the amount of ozone produced at the ozone generators' outlet. With the help of an integrated automated zero calibration device, the instrument has an automatic zero calibration capability that can automatically calibrate the ozone analyzer's zero point when ozone is pumped in, ensuring that the zero point is stabilized. The instrument has a 24-hour continuous operating cycle.
Measurement features: patented process, dual optical path UV absorption method principle, foreign long-life UV LED light source, can be run continuously to ensure the stability of the detection concentration.
Testing method: dual optical path UV optical absorption method, long-life light source system, to ensure the accuracy of measurement.
Real-time calibration: with automatic zero correction function, the system will automatically complete the zero calibration operation in the case of ozone.
Measuring Principle: Based on Lambert-Beer law, accurate measurement by photometric absorption principle.
Light source system: foreign long-life UV LED light source system, about 30,000-50,000 hours, free warranty for 2 years.
Usage: Indoor installation, equipped with power supply and signal terminal.
Light cell system: Separate light cell and gas chamber structure, no leakage, high pressure resistance, high flow sampling gas impact resistance.
model | UVOZ-3300C |
Measure the range | 0-300g/Nm3 |
Optional range | 0-400g/Nm3;0-200g/Nm3;0-100g/Nm3;0-50g/Nm3;0-10000ppm; |
Light source life | About 30,000-50,000 hours; |
Sampling method | Positive pressure sampling, negative pressure sampling (optional); |
Display interface | 4.3-inch touch screen operation interface; |
Content interface | Ozone concentration, temperature, pressure; (yield calculation and data recording can be customized) |
additional function | Temperature compensation, pressure compensation; |
Display unit | Option of g / Nm 3, mg / NL,% WT; |
display resolution | 0.01g/Nm3; |
gas-flow rate | 0.5L±0.2L/min; |
input pressure | <0.1MPa; |
Concentration error | ≤0.5%FS; |
linear error | ≤0.5%FS; |
precision | ≤±3% |
zero drift | <±0.3%.FS; |
reaction time | Signal 0.03 seconds, display 0.3 seconds; |
ambient temperature | -20~50℃ |
Pipe interface mode | Quick twist (stainless steel); |
Tandem sample caliber | Φ 8 (8mm * 6mm) (optional); |
Bypass sampling caliber | Φ6(6mm*4mm); |
communication mode | RS-485; |
Output method | 4-20 mA (active); |
Following the electrical signal | High alarm point following the electrical signal, low alarm point following the electrical signal; |
source | AC 110-220V; |
size |
133mm (height) 482mm (width) 300mm (deep), 19-inch 3U chassis; (Note 1 mg/L = 1 g/m3 = 467 PPM); |
Free warranty | 24 months (host sensor); |
Ozone generator manufacturers, municipal water industry, industrial wastewater industry, fine chemical industry, food and drinking water industry, space disinfection industry, swimming pool disinfection industry, flavor synthesis industry and other industries using ozone generators.